How it is worked out
A gallon of water weighs 8.33 pounds, and it takes 1 BTU to raise a pound of water by 1 degree. Over an hour, each gallon per minute is 60 gallons, which is about 500 pounds.
BTU per hour = gallons per minute × 500 × temperature rise
A worked example
Heating 4 gallons a minute from 50 to 120 degrees is a 70 degree rise. 4 × 500 × 70 is 140,000 BTU per hour, or about 41 kilowatts.
Where this turns up
- Checking whether a tankless water heater can keep up with two showers in winter, when the incoming water is cold.
- Working out the heat a hydronic loop is delivering from its flow and the temperature drop across it.
- Sizing a heat exchanger for a pool, spa or snow-melt system.
This is the heat delivered to the water. A burner's input rating is higher, because no appliance is 100% efficient. Choosing equipment should follow the manufacturer's sizing guide.
Common questions
Does the 500 change for glycol?
Yes. Antifreeze mixes carry less heat than plain water, so the figure drops, to roughly 450 for a 50% mix.
How we know this calculator is right
Before this calculator went on the site, 6 answers were worked out separately from its code, by hand or straight from the formula above. Each time this page loads, your own browser runs the calculator on those same numbers and compares. Turn on JavaScript to see the comparison.
See every check
| Numbers used | Result | Worked out separately | This calculator |
|---|
What this proves: the calculator does the arithmetic of the formula shown, correctly. What it cannot prove: your measurements, or figures such as coverage per bag, waste and spacing, which are typical starting values you can change. Go by the product label and your local code.